This draft hazard analysis covers hazards the EVCore diagnostic brick can cause or fail to prevent while testing a device under test (DUT). Hazards include energizing outputs, routing relays, injecting Kelvin current, and measuring circuits that may carry external energy from a battery or a spinning motor. Customer-facing misdiagnosis is included because a wrong conclusion can lead to an unsafe repair. Hardware controls listed here are proposals until the schematic confirms them. Severity ratings are qualitative until rated measurement voltage and category are set. See Applicable Standards and Hardware Open Items for related decisions.

Severity scale

Firmware can reduce these hazards but must never be the only protection. Every S4 hazard needs an independent hardware control.

Hazards

Follow-ups

  • Item 7 turns the firmware controls above into numbered safety requirements (SR-xx) that trace back to these hazard IDs, each proven by named tests.
  • Hardware-engineer review: confirm or replace each hardware control, and add hazards specific to the final schematic (for example grounding and isolation between USB, CAN, and the DUT battery).
  • Re-rate severities once the rated measurement voltage and category are set.